Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.406
Filtrar
1.
Ann Plast Surg ; 92(4S Suppl 2): S200-S203, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556673

RESUMO

BACKGROUND: The use of left ventricular assist devices (LVADs) for patients with end-stage cardiac failure awaiting heart transplantation has become increasingly common. However, ventricular assist device-related infections remain a major problem complicating their long-term use. Retrospective review has previously shown a decrease in lifetime return to operating room (RTOR) with no change in 90-day complications when a muscle or omental flap is used for coverage after washout for infection. We wished to determine if early plastic surgery intervention led to a decreased length of stay for these patients. METHODS: Patients with LVAD readmitted for LVAD infection at a single institution from 2008 to 2021 were identified using a preexisting database. Patients were followed retrospectively for an average of 3.2 years. Patient demographics, preoperative diagnosis/disease state, type of ventricular assist device inserted, postoperative day of ventricular assist device infection onset, definitive device coverage, timing of coverage procedure after the initial washout for infection, type of flap used for coverage, 90-day complications after definitive coverage, and lifetime return to operating room for infection were reviewed. Comparison analysis with χ2 and analysis of variance testing was used to analyze outcomes. RESULTS: Of 568 patients admitted with an LVAD infection, 104 underwent operative debridement and closure by plastic and reconstructive surgery (PRS) or cardiothoracic surgery (CTS). Fifty-three underwent PRS closure, and 51 underwent CTS closure. There was an increased incidence of diabetes among the PRS group (P < 0.001); otherwise, there was no difference in baseline characteristics. There was increased RTOR over a lifetime with CTS closure compared with PRS (P = 0.03) and increased 90-day risk of infection (P = 0.007). Patients with PRS closure had an increased risk of postoperative hematoma (P = 046). Plastic and reconstructive surgery was typically consulted on hospital day 10. Both PRS and CTS closure patients were discharged on postoperative day 7, on average (P = 0.542). CONCLUSIONS: Plastic surgery involvement with surgical decision making and closure of infected LVAD devices has a decrease in lifetime RTOR and decreased 90-day complications related to infections. There may be a benefit to earlier PRS consultation for coverage assessment.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Infecções Relacionadas à Prótese , Cirurgia Plástica , Humanos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Salas Cirúrgicas , Infecções Relacionadas à Prótese/etiologia , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento
2.
J Cardiothorac Surg ; 19(1): 167, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561765

RESUMO

BACKGROUND: The implantation of left ventricular assist devices (LVADs) as a bridge to transplantation or as destination therapy in end-stage heart failure patients is frequently complicated by the emergence of ventricular arrhythmias (VAs). These arrhythmias have been implicated in precipitating deleterious clinical outcomes, increased mortality rates and augmented healthcare expenditures. CASE PRESENTATION: We present a challenging case of a 49-year-old male with a history of dilated cardiomyopathy who received an LVAD. Post-implantation, the patient suffered from intractable VAs, leading to multiple rehospitalizations and hemodynamic deterioration. Despite exhaustive medical management and electrical cardioversion attempts, the patient's VAs persisted, ultimately necessitating prioritization for cardiac transplantation. DISCUSSION: This case highlights the challenges in managing VAs in LVAD patients and the importance of multidisciplinary collaboration. While pharmacological intervention is the initial strategy, catheter ablation may be considered in selected cases when medication is insufficient. In instances of intractable VAs, expeditious listing for heart transplantation as a high-priority candidate is advisable when feasible.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Masculino , Humanos , Pessoa de Meia-Idade , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Arritmias Cardíacas/etiologia , Hemodinâmica , Cardioversão Elétrica , Resultado do Tratamento
3.
Eur Rev Med Pharmacol Sci ; 28(6): 2199-2206, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38567583

RESUMO

OBJECTIVE: Pediatric heart failure is an important cause of morbidity and mortality in childhood. Left ventricular assist devices (L-VAD) are used for bridging to transplantation in patients with indications for heart transplantation. PATIENTS AND METHODS: The children included in the study were patients who underwent implantation of an L-VAD due to advanced heart failure at Ege University Faculty of Medicine Hospital between January 2009 and January 2023. RESULTS: Of the 33 patients who underwent L-VAD implantation, 16 (48.5%) were female and 17 (51.5%) were male. The median age at surgery was 13 years (IQR, 9.5-15). The median weight was 44 kg (IQR, 25.65-52), the median height was 158 cm (IQR, 134.5-168.5), and the median body surface area was 1.37 m2 (IQR, 0.95-1.51). All patients who underwent L-VAD implantation had an echocardiographic diagnosis of dilated cardiomyopathy. The patients underwent a median of 16 (IQR, 9-21) ECGs, and the median number of 24-hour Holter ECGs obtained was 3 (IQR, 2-5). Arrhythmias that occurred after L-VAD implantation were classified as atrial and ventricular. Ventricular arrhythmia included ventricular tachycardia (VT) lasting for more than 30 seconds (sustained VT), VT lasting for less than 30 seconds (nonsustained VT), and ventricular fibrillation. Atrial arrhythmias included atrial flutter, atrial fibrillation, supraventricular tachycardia, and atrial ectopic tachycardia. During the follow-up, atrial or ventricular arrhythmias were observed in 11 (33%) patients. The most common rhythm disturbances before L-VAD implantation were ventricular arrhythmias, while after the surgery, atrial arrhythmias were found to be the most frequent. A total of 5 patients underwent cardioversion (n=2) or defibrillation (n=3) due to arrhythmia. CONCLUSIONS: In patients undergoing L-VAD implantation, rhythm disorders that could normally lead to hemodynamic instability are frequently encountered. In these rhythm disorders, medical therapy should be attempted before resorting to cardioversion or defibrillation, and subsequently, more aggressive treatment methods should be considered.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Coração Auxiliar , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Masculino , Feminino , Criança , Adolescente , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações
5.
N Engl J Med ; 390(15): 1382-1393, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38587239

RESUMO

BACKGROUND: The effects of temporary mechanical circulatory support with a microaxial flow pump on mortality among patients with ST-segment elevation myocardial infarction (STEMI) complicated by cardiogenic shock remains unclear. METHODS: In an international, multicenter, randomized trial, we assigned patients with STEMI and cardiogenic shock to receive a microaxial flow pump (Impella CP) plus standard care or standard care alone. The primary end point was death from any cause at 180 days. A composite safety end point was severe bleeding, limb ischemia, hemolysis, device failure, or worsening aortic regurgitation. RESULTS: A total of 360 patients underwent randomization, of whom 355 were included in the final analysis (179 in the microaxial-flow-pump group and 176 in the standard-care group). The median age of the patients was 67 years, and 79.2% were men. Death from any cause occurred in 82 of 179 patients (45.8%) in the microaxial-flow-pump group and in 103 of 176 patients (58.5%) in the standard-care group (hazard ratio, 0.74; 95% confidence interval [CI], 0.55 to 0.99; P = 0.04). A composite safety end-point event occurred in 43 patients (24.0%) in the microaxial-flow-pump group and in 11 (6.2%) in the standard-care group (relative risk, 4.74; 95% CI, 2.36 to 9.55). Renal-replacement therapy was administered to 75 patients (41.9%) in the microaxial-flow-pump group and to 47 patients (26.7%) in the standard-care group (relative risk, 1.98; 95% CI, 1.27 to 3.09). CONCLUSIONS: The routine use of a microaxial flow pump with standard care in the treatment of patients with STEMI-related cardiogenic shock led to a lower risk of death from any cause at 180 days than standard care alone. The incidence of a composite of adverse events was higher with the use of the microaxial flow pump. (Funded by the Danish Heart Foundation and Abiomed; DanGer Shock ClinicalTrials.gov number, NCT01633502.).


Assuntos
Coração Auxiliar , Infarto do Miocárdio com Supradesnível do Segmento ST , Choque Cardiogênico , Idoso , Feminino , Humanos , Masculino , Coração Auxiliar/efeitos adversos , Incidência , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Choque Cardiogênico/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Resultado do Tratamento , Circulação Assistida/efeitos adversos , Circulação Assistida/instrumentação , Circulação Assistida/métodos
6.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38613845

RESUMO

OBJECTIVES: Myocardial recovery in children supported by a durable left ventricular assist device is a rare, but highly desirable outcome because it could potentially eliminate the need for a cardiac transplant and the lifelong need for immunosuppressant therapy and the risk of complications. However, experience with this specific outcome is extremely limited. METHODS: All patients < 19 years old supported by a durable left ventricular assist device from the European Registry for Patients with Mechanical Circulatory Support database were included. Participating centres were approached for additional follow-up data after explantation. Associated factors for explantation due to myocardial recovery were explored using Cox proportional hazard models. RESULTS: The incidence of recovery in children supported by a durable left ventricular assist device was 11.7% (52/445; median duration of support, 122.0 days). Multivariable analyses showed body surface area (hazard ratio 0.229; confidence interval 0.093-0.565; P = 0.001) and a primary diagnosis of myocarditis (hazard ratio 4.597; confidence interval 2.545-8.303; P < 0.001) to be associated with recovery. Left ventricular end-diastolic diameter in children with myocarditis was not associated with recovery. Follow-up after recovery was obtained for 46 patients (88.5%). Sustained myocardial recovery was reported in 33/46 (71.7%) at the end of the follow-up period (28/33; >2 year). Transplants were performed in 6/46 (11.4%) (in 5 after a ventricular assist device was reimplanted). Death occurred in 7/46 (15.2%). CONCLUSIONS: Myocardial recovery occurs in a substantial portion of paediatric patients supported with durable left ventricular assist devices, and sustainable recovery is seen in around three-quarters of them. Even children with severely dilated ventricles due to myocarditis can show recovery. Clinicians should be attentive to (developing) myocardial recovery. These results can be used to develop internationally approved paediatric weaning guidelines.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Miocardite , Humanos , Criança , Adulto Jovem , Adulto , Coração Auxiliar/efeitos adversos , Miocardite/cirurgia , Miocárdio , Diástole , Insuficiência Cardíaca/cirurgia , Resultado do Tratamento
7.
Arq Bras Cardiol ; 121(1): e20230537, 2024.
Artigo em Português, Inglês | MEDLINE | ID: mdl-38511808

RESUMO

This case report describes the exercise program on a hospitalized 54-year-old male patient with cardiogenic shock waiting for a heart transplant assisted by an intra-aortic balloon pump, a temporary mechanical circulatory support device. The temporary mechanical circulatory support device, an intra-aortic balloon pump, was placed in the left subclavian artery, enabling the exercise protocol. Measurements and values from Swan-Ganz catheter, blood sample, brain natriuretic peptide (NT-proBNP), and high-sensitivity C-reactive protein (hs-CRP), as well as the six-minute walk test (6MWT) and venous oxygen saturation (SvO2) were obtained before and after an exercise protocol. The exercise training protocol involved the use of an unloaded bed cycle ergometer once a day, for a maximum of 30 minutes, to the tolerance limit. No adverse events or events related to the dislocation of the intra-aortic balloon pump were observed during the exercise protocol. The exercise program resulted in higher SvO2 levels, with an increased 6MWT with lower Borg dyspnea scores (312 meters vs. 488 meters and five points vs. three points, respectively). After completing the ten-day exercise protocol, the patient underwent a non-complicated heart transplant surgery and a full recovery in the ICU. This study showed that exercise is a feasible option for patients with cardiogenic shock who are using an intra-aortic balloon pump and that it is well-tolerated with no reported adverse events.


O presente relato de caso descreve o programa de exercícios aplicado a um paciente do sexo masculino, de 54 anos, internado com choque cardiogênico, aguardando transplante cardíaco e assistido por balão intra-aórtico, um dispositivo de suporte circulatório mecânico temporário. O dispositivo de suporte circulatório mecânico temporário, um balão intra-aórtico, foi colocado na artéria subclávia esquerda, possibilitando o protocolo de exercícios. Antes e após um protocolo de exercícios, foram obtidos dados a partir de cateter de Swan-Ganz, amostra de sangue, peptídeo natriurético cerebral (NT-proBNP), proteína C reativa de alta sensibilidade (PCR-as), teste de caminhada de seis minutos (TC6min) e medição da saturação venosa de oxigênio (SvO2). O protocolo de treinamento físico envolveu a utilização de um cicloergômetro adaptado ao leito, sem carga, uma vez ao dia, por no máximo 30 minutos, até o limite da tolerância. Não foram observados eventos adversos tampouco relacionados ao deslocamento do balão intra-aórtico durante o protocolo de exercícios. O programa de exercícios resultou em maior SvO2 com aumento do TC6min e menores escores de dispneia de Borg (312 metros vs. 488 metros e cinco pontos vs. três pontos, respectivamente). Após completar o protocolo de exercícios de dez dias, o paciente foi submetido a uma cirurgia de transplante cardíaco sem complicações e recuperação total na UTI. O presente estudo demonstrou que o exercício é uma opção viável para pacientes com choque cardiogênico em uso de balão intra-aórtico e que é bem tolerado, além de não haver relatos de eventos adversos.


Assuntos
Transplante de Coração , Coração Auxiliar , Masculino , Humanos , Pessoa de Meia-Idade , Choque Cardiogênico/terapia , Choque Cardiogênico/etiologia , Transplante de Coração/efeitos adversos , Caminhada , Balão Intra-Aórtico/efeitos adversos , Balão Intra-Aórtico/métodos , Coração Auxiliar/efeitos adversos , Resultado do Tratamento
8.
Antimicrob Agents Chemother ; 68(4): e0172823, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38470133

RESUMO

Left ventricular assist devices (LVAD) are increasingly used for management of heart failure; infection remains a frequent complication. Phage therapy has been successful in a variety of antibiotic refractory infections and is of interest in treating LVAD infections. We performed a retrospective review of four patients that underwent five separate courses of intravenous (IV) phage therapy with concomitant antibiotic for treatment of endovascular Pseudomonas aeruginosa LVAD infection. We assessed phage susceptibility, bacterial strain sequencing, serum neutralization, biofilm activity, and shelf-life of phage preparations. Five treatments of one to four wild-type virulent phage(s) were administered for 14-51 days after informed consent and regulatory approval. There was no successful outcome. Breakthrough bacteremia occurred in four of five treatments. Two patients died from the underlying infection. We noted a variable decline in phage susceptibility following three of five treatments, four of four tested developed serum neutralization, and prophage presence was confirmed in isolates of two tested patients. Two phage preparations showed an initial titer drop. Phage biofilm activity was confirmed in two. Phage susceptibility alone was not predictive of clinical efficacy in P. aeruginosa endovascular LVAD infection. IV phage was associated with serum neutralization in most cases though lack of clinical effect may be multifactorial including presence of multiple bacterial isolates with varying phage susceptibility, presence of prophages, decline in phage titers, and possible lack of biofilm activity. Breakthrough bacteremia occurred frequently (while the organism remained susceptible to administered phage) and is an important safety consideration.


Assuntos
Bacteriemia , Bacteriófagos , Coração Auxiliar , Terapia por Fagos , Infecções por Pseudomonas , Humanos , Pseudomonas aeruginosa , Coração Auxiliar/efeitos adversos , Infecções por Pseudomonas/terapia , Infecções por Pseudomonas/microbiologia , Antibacterianos/uso terapêutico , Prófagos , Bacteriemia/tratamento farmacológico
9.
J Extra Corpor Technol ; 56(1): 10-15, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38488713

RESUMO

BACKGROUND: Left ventricular assist device (LVAD) candidates are at increased risk of immune dysregulation and infectious complications. To attenuate the elevated proinflammatory cytokine levels and associated adverse clinical outcomes, it has been postulated that extracorporeal blood purification could improve the overall survival rate and morbidity of patients undergoing LVAD implantation. METHODS: We retrospectively reviewed prospectively collected data of 15 patients who underwent LVAD implantation at our center between January 2021 and March 2022. Of these, 15 (100%) who received HeartMate 3™ (St. Jude Medical, Abbott, MN, USA) device were eligible. Intraoperatively, patients were single randomized 1:1:1 to three groups: group 1, patients who received Cytosorb therapy (n = 5; installed in the CPB circuit); group 2, patients who received Jafron HA330 (n = 5; installed in the CPB circuit); and control group 3, patients who did not receive filter (n = 5; usual care, neither Cytosorb nor Jafron during CPB). Baseline patient characteristics and intraoperative data were compared between the groups. Blood sample analyses were performed to assess the levels of inflammatory markers (IL-1, 6, 8; CRP, Leukocyte, Lactate, PCT, NT-proBNP, TNF-α) in both preoperative and postoperative data. RESULTS: Baseline patient characteristics were similar in all three groups. We found that IL1α; IL 6; IL8; Lactatedehydrogenase, PCT, pro-BNP, CRP; Leukocyte, and TNFα levels significantly increased with LVAD implantation and that neither Cytosorb nor Jafron influenced this response. In-hospital mortality and overall survival during follow-up were similar among the groups. CONCLUSION: Our preliminary results showed that hemoadsorption therapy using Cytosorb or Jafron hemoadsorption (HA) 330 may not be clinically beneficial for patients with advanced heart failure undergoing LVAD implantation. Large prospective studies are needed to evaluate the potential role of HA therapy in improving outcomes in patients undergoing LVAD implantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estudos Retrospectivos , Coração Auxiliar/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento
10.
Intensive Crit Care Nurs ; 82: 103658, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38431985

RESUMO

BACKGROUND: Surgical wound infection is the most frequent type of care health associated infection. Lack of knowledge about the prevention of surgical wound infection in patients undergoing left ventricular assist device implantation could significantly undermine the potential benefits of surgical intervention. OBJECTIVES: This study aimed to map the recommendations for adult patients undergoing left ventricular assist device implantation. DESIGN: This is a scoping review, being registered in the Open Science Framework under DOI https://doi.org/10.17605/OSF.IO/Q76B3 (https://osf.io/q76b3/). METHOD: Left ventricular assist device coordinators and nurse specialists in dermatology and stomatherapy conducted a scoping review in Scopus, The Cochrane Database of Systematic Reviews, Cumulative Index to Nursing and Allied Health Literature (CINAHL), limited to the period between 2015 and 2022. The results of this scoping review will be discussed and presented in separate articles. This paper will synthesize research evidence on the perioperative topic. RESULTS: The initial searches resulted in 771 studies. Sixty nine met the eligibility criteria and were included in the scoping review. Eight articles addressing the perioperative topic that answered the question of this article were included. CONCLUSION: Although this scoping review included heterogeneous, and scarce studies with left ventricular assist device patients. As such, there are many promising future research directions for this topic. IMPLICATIONS FOR CLINICAL PRACTICE: Infection surveillance should be an integral part of left ventricular assist device implantation programs in health care institutions. Velvet completely buried in subcutaneous tissues reduces transmission system infection. Triple tunnel method reduces transmission system infection risk.


Assuntos
Coração Auxiliar , Infecção da Ferida Cirúrgica , Adulto , Humanos , Infecção da Ferida Cirúrgica/prevenção & controle , Coração Auxiliar/efeitos adversos , Revisões Sistemáticas como Assunto
11.
Int J Artif Organs ; 47(4): 269-279, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38506302

RESUMO

Centrifugal blood pumps can be used for treating heart failure patients. However, pump thrombosis has remained one of the complications that trouble clinical treatment. This study analyzed the effect of impeller shroud on the thrombosis risk of the blood pump, and predicted areas prone to thrombosis. Multi-constituent transport equations were presented, considering mechanical activation and biochemical activation. It was found that activated platelets concentration can increase with shear stress and adenosine diphosphate(ADP) concentration increasing, and the highest risk of thrombosis inside the blood pump was under extracorporeal membrane oxygenation (ECMO) mode. Under the same condition, ADP concentration and thrombosis index of semi-shroud impeller can increase by 7.3% and 7.2% compared to the closed-shroud impeller. The main reason for the increase in thrombosis risk was owing to elevated scalar shear stress and more coagulation promoting factor-ADP released. The regions with higher thrombosis potential were in the center hole, top and bottom clearance. As a novelty, the findings revealed that impeller shroud can influence mechanical and biochemical activation factors. It is useful for identifying potential risk regions of thrombus formation based on relative comparisons.


Assuntos
Coração Auxiliar , Estresse Mecânico , Trombose , Trombose/etiologia , Trombose/fisiopatologia , Trombose/sangue , Humanos , Coração Auxiliar/efeitos adversos , Ativação Plaquetária , Modelos Cardiovasculares , Difosfato de Adenosina/metabolismo , Desenho de Prótese , Oxigenação por Membrana Extracorpórea/efeitos adversos , Fatores de Risco , Plaquetas/metabolismo
13.
Heart Fail Clin ; 20(2): 155-165, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38462320

RESUMO

Heart failure has become the leading cause of mortality in adult congenital heart disease (ACHD) patients after the fifth decade of life. There is scanty evidence supporting the use of guideline-directed medical therapy in ACHD, especially in systemic right ventricle or single ventricle physiology. In complex patients, diagnosing heart failure and timely referral for advanced therapies are challenging. Mechanical circulatory support has been significantly developed over the past decade and has recently emerged as a feasible therapeutic option for these patients. This review summarizes current evidence of mechanical circulatory support in this population, its potential uses, and challenges.


Assuntos
Cardiopatias Congênitas , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Adulto , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia , Cardiopatias Congênitas/diagnóstico , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração
14.
Am J Cardiol ; 217: 119-126, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38382702

RESUMO

This single-center, observational study assessed the impact of age, gender, and body mass index (BMI) in patients with cardiogenic shock (CS) on temporary mechanical circulatory support. All adult patients admitted to the Cleveland Clinic main campus Cardiac Intensive Care Unit (CICU) between December 1, 2015, to December 31, 2019, CICU with CS necessitating mechanical circulatory support (MCS) with intra-aortic balloon pump, Impella, or venous arterial-extra corporeal membrane oxygenation were retrospectively analyzed for this study. Baseline characteristics and 30-day outcomes were collected through physician-directed chart review. The impact of age, gender, and BMI on 30-day mortality was assessed using multivariable logistic regression. Kaplan-Meier survival curves were used to analyze the survival difference in specific subsets. A total of 393 patients with CS on temporary MCS were admitted to our CICU during the study period. The median age of our cohort was 63 years (interquartile range 54 to 70 years), median BMI was 28.50 kg/m2 (interquartile range 24.62 to 29.72) and 70% (n = 276) were men. In total, 22 patients >80 years had received MCS compared with 372 patients <80 years. Patients >80 years on MCS had significantly higher 30-day mortality compared with those <80 years (81.8% vs 49.3%, p = 0.006). Upon stratifying patients by BMI, 161 (41%) patients were found to have BMI ≥30 kg/m2 whereas 232 (59%) patients had BMI <30 kg/m2. Comparison of 30-day mortality revealed that patients with BMI ≥30 did significantly worse than patients with BMI <30 (59.6% vs 45.3%, p = 0.007). There was no difference in 30-day mortality between men and women. On multivariable logistic regression, both age and BMI had a positive linear relation with adjusted 30-day mortality whereas gender did not have a major effect. Advanced age and higher BMI are independently associated with worse outcomes in patients with CS on MCS. Utilizing a strict selection criterion for patients in CS is pertinent to derive the maximum benefit from advanced mechanical support.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Masculino , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/terapia , Choque Cardiogênico/etiologia , Índice de Massa Corporal , Estudos Retrospectivos , Resultado do Tratamento , Coração Auxiliar/efeitos adversos , Balão Intra-Aórtico
15.
Artif Organs ; 48(5): 559-566, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38400624

RESUMO

BACKGOUND: Infections of the left ventricular assist device (LVAD) driveline are a dreaded complication that results in high mortality and morbidity. METHOD: We retrospectively reviewed five consecutive patients with severe continuous-flow LVAD (HVAD, Heartmate 2, and Heartmate 3) driveline infection. These infections, which developed on an average of 960.4 ± 843.9 days after LVAD placement, were refractory to systemic antibiotics and local wound care. All were treated with extensive surgical debridement, local installation of absorbable antibiotic-loaded calcium sulfate beads (vancomycin and tobramycin), primary wound closure, and 6 weeks of systemic antibiotics after surgery. RESULTS: Four patients had resolution of DLI, and one had a recurrent infection at another part of the driveline 7 months after the complete resolution of the previous site. This patient was successfully treated with debridement and bead placements. Three patients still have their LVADs, while two received orthotopic heart transplants. At the time of the transplant, there was no evidence of gross infection of the LVAD drivelines or pumps. At the average follow-up time of 425.8 ± 151 days, no patients have an active infection. CONCLUSION: Treatment of LVAD driveline infection with absorbable antibiotic beads with primary wound closure is a viable option and merits further investigation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Infecções Relacionadas à Prótese , Humanos , Antibacterianos/uso terapêutico , Estudos Retrospectivos , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Vancomicina , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia
16.
Artif Organs ; 48(5): 550-558, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38409825

RESUMO

BACKGROUND: In conventional left ventricular assist devices (LVAD), a separate outflow graft is sutured to the ascending aorta. Novel device designs may include a transventricular outflow cannula crossing the aortic valve (AV). While transversal ventricular dimensions are well investigated in patients with severe heart failure, little is known about the longitudinal dimensions. These dimensions are, however, particularly critical for the design and development of mechanical circulatory support (MCS) devices with transaortic outflow cannula. METHODS: In an explorative retrospective cohort study at the University Medical Center Freiburg, Germany, the longitudinal cardiac dimensions of patients undergoing computed tomography angiography (CTA) before and, if available, after LVAD implantation were analyzed. Among others, the following dimensions were assessed: (a) apex to AV, (b) apex to mitral valve, (c) AV to sinotubular junction (STJ), (d) apex to STJ, (e) apex to brachiocephalic artery (BCA), and (f) AV to BCA. RESULTS: In total, 44 LVAD patients (36 male, age 55.8 years, height 1.75 m) were included. The longitudinal cardiac dimensions were (a) 114.5 ± 12.1 mm, (b) 108.0 ± 12.4 mm, (c) 20.9 ± 2.9, (d) 135.4 ± 13.4 mm, (e) 206.0 ± 18.3, and (f) 91.5 ± 9.8 mm. Postoperatively, (a) and (b) decreased by 31.5% and 39.5%, respectively (N = 14). CONCLUSIONS: Longitudinal cardiac dimensions may be reduced by up to 40% after LVAD implantation. A better knowledge of these dimensions and their postoperative alterations in LVAD patients may improve surgical planning and help to design MCS devices with transventricular outflow cannula.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Procedimentos Cirúrgicos Torácicos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Aorta Torácica/cirurgia , Aorta , Valva Aórtica , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Resultado do Tratamento
17.
Artif Organs ; 48(4): 408-417, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38380771

RESUMO

BACKGROUND: Mechanical cardiac support is currently an effective strategy to reduce morbidity and mortality in pediatric patients. However, solid evidence regarding the feasibility of intracorporeal devices in children still needs to be provided. We report our 10-year experience with intracorporeal left ventricular assist devices (LVAD) in children. MATERIALS AND METHODS: We included all patients undergoing intracorporeal, continuous-flow LVAD implantation between 2012 and 2022. Baseline and postoperative data were collected from the institutional database. RESULTS: Seven HeartWare and 4 HeartMate3 were implanted in 11 patients (median age 13.9 years, median body surface area - BSA - 1.42 m2, IQR 1.06-1.68). The most frequent indication to LVAD implant was dilated cardiomyopathy (72.7%). All candidates underwent a thorough preoperative advanced imaging. Three-dimensional reconstructions and implant fit simulation were performed when BSA was <1.2 m2, weight <30 kg, or internal transverse thoracic diameter <20 cm. There was no operative death. The most common postoperative complication was surgical re-exploration due to bleeding (27.3%). One patient died of severe neurological complications after about 3 months of hospitalization. No late deaths or unplanned re-hospitalizations occurred in the remaining 10, 6 of whom were discharged home. There were no major complications at the follow-up. All survivors underwent successful heart transplantation. CONCLUSIONS: Intracorporeal LVAD implantation proved to be a potentially feasible and safe option in young teenagers and children whose BSA was >1.0 m2. In borderline cases, the 3D reconstruction with implant fit simulation can effectively help to identify those patients who can safely undergo intrathoracic LVAD implantation.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Adolescente , Humanos , Criança , Insuficiência Cardíaca/cirurgia , Implantação de Prótese/efeitos adversos , Complicações Pós-Operatórias , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
18.
J Am Heart Assoc ; 13(5): e031305, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38420763

RESUMO

BACKGROUND: Preoperative kidney dysfunction is a risk factor for right heart failure (RHF) after implantation of a left ventricular assist device (LVAD). However, characteristic kidney function trajectories before and after post-LVAD RHF are uncertain, so we investigated this. METHODS AND RESULTS: We identified individuals who received primary continuous-flow LVAD implantation from July 1, 2014 to December 31, 2017 in the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) data set. Incident RHF was ascertained using the INTERMACS definition at 1 and 3 months and classified as transient or persistent. Kidney function trajectories before and after RHF onset, and relationships of baseline kidney function with RHF risk at the different time points, were assessed. We identified 8076 LVAD recipients who met inclusion criteria. Incident RHF was present at 1 month in 26.4%. There were 4850 individuals with follow-up at 3 months, with incident RHF in 4.2%. Kidney function trajectories differed from pre-LVAD implantation to 1-month follow-up by RHF category, with those developing persistent RHF having no improvement in baseline kidney function. For trajectories before the 3-month RHF ascertainment time, the shape was similar for those with and without RHF, with lower estimated glomerular filtration rate levels among those who developed RHF. Baseline estimated glomerular filtration rate levels below the normal range were associated with higher risk of RHF at 1 and 3 months. CONCLUSIONS: In LVAD recipients, preimplantation kidney function and subsequent kidney function trajectories differed substantially by RHF at 1 and 3 months postimplantation, even after adjustment for several confounders. This may demonstrate bidirectional associations between kidney function and right ventricular function in LVAD recipients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estudos Retrospectivos , Fatores de Risco , Coração Auxiliar/efeitos adversos , Rim
19.
Heart Fail Rev ; 29(2): 559-569, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38329583

RESUMO

The use of left ventricular assist devices (LVAD) has significantly increased in the last years, trying to offer a therapeutic alternative to heart transplantation, in light also to the significant heart donor shortage compared to the growing advanced heart failure population. Despite technological improvements in the devices, LVAD-related mortality is still fairly high, with right heart failure being one of the predominant predictors. Therefore, many efforts have been made toward a thorough right ventricular (RV) evaluation prior to LVAD implant, considering clinical, laboratory, echocardiographic, and invasive hemodynamic parameters. However, there is high heterogeneity regarding both which predictor is the strongest as well as the relative cut-off values, and a consensus has not been reached yet, increasing the risk of facing patients in which the distinction between good or poor RV function cannot be surely reached. In parallel, due to technological development and availability of mechanical circulatory support of the RV, LVADs are being considered even in patients with suboptimal RV function. The aim of our review is to analyze the current evidence regarding the role of RV function prior to LVAD and its evaluation, pointing out the extreme variability in parameters that are currently assessed and future prospective regarding new diagnostic tools. Finally, we attempt to gather the available information on the therapeutic strategies to use in the peri-operative phase, in order to reduce the incidence of RV failure, especially in patients in which the preoperative evaluation highlighted some conflicting results with regard to ventricular function.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Disfunção Ventricular Direita , Humanos , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia , Transplante de Coração/efeitos adversos , Ecocardiografia , Estudos Retrospectivos
20.
J Int Med Res ; 52(2): 3000605231214943, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38318647

RESUMO

A left ventricular assist device is a mechanical device that is surgically implanted in the heart to partially or completely replace the function of the heart. Left ventricular assist devices are of vital importance in the treatment of patients with heart failure. There are different recommendations for the postoperative care of patients undergoing left ventricular assist device implantation in different countries, and no uniform standard has been developed. The first implantation of a left ventricular assist device in Eastern China was performed in February 2021; since that date, 14 patients underwent implantation until February 2023. This report describes the postoperative care of these 14 patients with end-stage heart failure who underwent left ventricular assist device placement, all of whom were discharged with a good prognosis.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Cuidados Pós-Operatórios , Resultado do Tratamento , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração , China , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...